Products Description
gaZpro Ox Online Analyzer
Features :
| Control Card | : | Solid State Electronics Base |
| Range | : | Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2) |
| Resolution | : | Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2) |
| Display | : | 3 ½ Digit LED |
| Size | : | Standard Enclosure Size: H: - 200 mm W: - 180mm D: - 320 mm |
| Oper. Temperature | : | 0 – 50 deg C |
| Visual Indication | : | A) Pilot B) Warn C) Alarm |
| Controls | : | Optional: - A) Reset B) Accept |
| Parameter Setting | : | A) Zero B) Span C) Warn D) Alarm |
| Input Signals | : | Standard: - 4 – 20 mA. Optional: - 0 – 1 Vdc |
| Outputs | : | Standard: - 4 – 20mA. Recorder Output, Potential free Relay contacts for Alarms. Optional: - Repeater output for Alarms, 0 – 1 vDC. Recorder Output |
| Power Supply | : | Standard: - 220 vAC. 50 Hz Optional: - 110 vAC. 50 Hz |
| Mounting | : | Standard: Panel Mounting |
| Mounting | : | Standard: Panel Mounting |
| Flow | : | 100 – 200 ml / min. |
| Pressure | : | Gas Pressure on Sensor head should not exceed 1 Kg. / cm2 |
| Connections | : | Standard: - ¼ “ NPT for 1/P and O/P Optional: - As per specifications |
| Sensor Type | : | Electrochemical |
| Sensor Life | : | Max. 2 years (in fresh air) |
| Response Time | : | 90% of FSD in <30 Sec. |
Products Description
gaZpro Ox - FLP Online Analyzer
Explosion proof version for application in II A/B, IIC
Features :
| Control Card | : | Solid State Electronics Base |
| Range | : | Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2) |
| Resolution | : | Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2) |
| Display | : | 3 ½ Digit LED |
| Size | : | Standard Enclosure Size: H: - 200 mm W: - 180mm D: - 320 mm |
| Oper. Temperature | : | 0 – 50 deg C |
| Visual Indication | : | A) Pilot B) Warn C) Alarm |
| Controls | : | Optional: - A) Reset B) Accept |
| Parameter Setting | : | A) Zero B) Span C) Warn D) Alarm |
| Input Signals | : | Standard: - 4 – 20 mA. Optional: - 0 – 1 Vdc |
| Outputs | : | Standard: - 4 – 20mA. Recorder Output, Potential free Relay contacts for Alarms. Optional: - Repeater output for Alarms, 0 – 1 vDC. Recorder Output |
| Power Supply | : | Standard: - 220 vAC. 50 Hz Optional: - 110 vAC. 50 Hz |
| Mounting | : | Standard: Panel Mounting |
| Mounting | : | Standard: Panel Mounting |
| Flow | : | 100 – 200 ml / min. |
| Pressure | : | Gas Pressure on Sensor head should not exceed 1 Kg. / cm2 |
| Connections | : | Standard: - ¼ “ NPT for 1/P and O/P Optional: - As per specifications |
| Sensor Type | : | Electrochemical |
| Sensor Life | : | Max. 2 years (in fresh air) |
| Response Time | : | 90% of FSD in <30 Sec. |
| Hazardous Protection | : | Explosion proof version for application in IIA/IIB, IIC |